Daikin VRV Systems

DAIKIN VRV SYSTEMS

Daikin VRV Systems for Homes, Offices & Commercial Projects

Focus Aircon handles VRV projects as a complete HVAC scope — from site assessment and system planning to capacity selection, indoor-unit zoning, refrigerant piping, installation, testing, commissioning and after-sales support.

Daikin model availability and final system selection should be confirmed against the latest project-specific technical documentation before quotation.

Daikin VRV Home system outdoor unit
APPLICATION-LED SELECTION

Daikin VRV Solutions for Different Project Sizes

For Focus Aircon's project work, it is useful to separate residential VRV, small-office VRV and larger commercial VRV rather than mixing every range into one catalogue.

Homes & Villas

VRV Home

Compact single-outdoor-unit VRV designed for residences where several indoor units need to be connected while reducing the number of outdoor units.

4 / 5 / 6 HPSingle PhaseUp to 8 indoor units*
ENQUIRE NOW →
Offices & Shops

VRV S

A compact VRV platform aimed at small offices and shops, with a wider capacity range than VRV Home and a choice of indoor and outdoor units.

4–12 HP11.2–33.5 kWHeat Pump
ENQUIRE NOW →
Commercial Projects

VRV Alpha

High-capacity Daikin VRV outdoor units for larger offices, showrooms and commercial HVAC applications, with single outdoor modules available across multiple HP classes.

6–26 HP single modulesCooling / Heat Pump3 Phase
ENQUIRE NOW →
VRV HOME

Daikin VRV Home — 4 HP, 5 HP & 6 HP

Designed for homes and residences where multiple rooms can be connected to one outdoor system. Daikin India lists both heat-pump and cooling-only outdoor-unit variants.

Heat Pump Series

Outdoor modelCapacityTypical use
RXYRQ4ARV164 HP · 11.2 kWSmaller homes / apartments
RXYRQ5ARV165 HP · 14.0 kWMedium-size residences
RXYRQ6ARV166 HP · 16.0 kWLarger homes / villas

Cooling Only Series

Outdoor modelCapacityVariant
RXRQ4ARV164 HP · 11.2 kWCooling only
RXRQ5ARV165 HP · 14.0 kWCooling only
RXRQ6ARV166 HP · 16.0 kWCooling only
Daikin-published VRV Home limits: up to 6 indoor units for the 4 HP and 5 HP installations, and up to 8 indoor units for the 6 HP installation. Daikin also lists a total piping length of up to 100 m and actual piping length up to 40 m, subject to the applicable design conditions.
VRV S · SMALL OFFICES & SHOPS

Daikin VRV S Outdoor Models by HP Capacity

VRV S is positioned by Daikin India for small offices and shops. The outdoor range listed by Daikin spans 4 HP through 12 HP, giving more capacity steps for light-commercial projects.

Outdoor modelHPCooling capacityApplication context
RX(Y)MQ4BRV164 HP11.2 kWSmall office / shop
RX(Y)MQ5BRV165 HP14.0 kWSmall office / shop
RX(Y)MQ6ARV166 HP16.0 kWOffice / retail
RX(Y)MQ8ARY168 HP22.4 kWMedium light-commercial space
RX(Y)MQ10BRY1610 HP28.0 kWMedium office / retail
RX(Y)MQ12BRY1612 HP33.5 kWLarger light-commercial space
Important: HP is a system capacity class, not a substitute for a proper heat-load calculation. Final outdoor capacity, indoor-unit combination, diversity/connection ratio and piping design should be selected from the actual project requirements.
VRV ALPHA · COMMERCIAL

Single-Outdoor Daikin VRV Alpha Models

For larger office and commercial projects, this page focuses on single outdoor-unit models. Combination-unit configurations can be engineered later when a project requires more capacity.

Cooling Only · RXQ Series

ModelHPCooling
RXQ6BRY166 HP16.0 kW
RXQ8BRY168 HP22.4 kW
RXQ10BRY1610 HP28.0 kW
RXQ12BRY1612 HP33.5 kW
RXQ14BRY1614 HP40.0 kW
RXQ16BRY1616 HP45.0 kW
RXQ18BRY1618 HP50.0 kW
RXQ20BRY1620 HP56.0 kW
RXQ22BRY1622 HP61.5 kW
RXQ24BRY1624 HP67.0 kW
RXQ26BRY1626 HP73.0 kW

Heat Pump · RXYQ Series

ModelHPCoolingHeating
RXYQ6BRY166 HP16.0 kW18.0 kW
RXYQ8BRY168 HP22.4 kW25.0 kW
RXYQ10BRY1610 HP28.0 kW31.5 kW
RXYQ12BRY1612 HP33.5 kW37.5 kW
RXYQ14BRY1614 HP40.0 kW45.0 kW
RXYQ16BRY1616 HP45.0 kW50.0 kW
RXYQ18BRY1618 HP50.0 kW56.0 kW
RXYQ20BRY1620 HP56.0 kW63.0 kW
RXYQ22BRY1622 HP61.5 kW69.0 kW
RXYQ24BRY1624 HP67.0 kW73.0 kW
RXYQ26BRY1626 HP73.0 kW73.0 kW
The 18–26 HP Alpha models above are shown as single outdoor modules based on Daikin India's current Alpha catalogue. Confirm exact availability, electrical requirements and project configuration before order.
INDOOR UNITS & ZONING

Build the VRV Around the Building — Not Just the Outdoor Unit

We can plan the indoor-unit mix around each room, floor and usage pattern. Depending on the project, VRV systems can use wall-mounted, cassette, ducted and other compatible indoor-unit formats.

Room-by-room zoning: bedrooms, cabins, meeting rooms, halls and other occupied spaces.
Indoor-unit selection: choose the appropriate indoor type and capacity for ceiling, wall or concealed installation.
Capacity planning: size the system from the building requirement rather than selecting HP only from room count.
Refrigerant piping: plan main runs, branches/refnets, pipe sizes, route lengths and level differences.
Controls: coordinate individual room control and central/control-system requirements where applicable.
Drainage & services: coordinate condensate drainage, power, access and service clearances.
END-TO-END VRV PROJECT DELIVERY

From First Site Visit to Final Handover

Because VRV is a project-based HVAC system, our role should be presented as complete project execution — not simply supply of an outdoor unit.

01

Site Survey

Review floor plans, room usage, ceiling conditions, outdoor-unit locations, access and installation constraints.

02

Load & Capacity Planning

Assess cooling requirements and determine suitable outdoor and indoor-unit capacities for each zone.

03

HVAC Planning & Layout

Plan indoor-unit locations, outdoor units, piping routes, refnets, drainage, controls and service access.

04

BOQ & Proposal

Prepare the equipment schedule, piping/material scope and project quotation based on the design.

05

Installation

Execute outdoor and indoor installation, refrigerant piping, insulation, drainage, wiring and controls.

06

Testing & Pressure Checks

Carry out the required installation checks, pressure testing, leak checks and evacuation before commissioning.

07

Commissioning

Start up the system, configure controls and verify operating performance across the connected zones.

08

Handover & AMC

Complete client handover and continue with preventive maintenance and service support when required.

PROJECT APPLICATIONS

VRV Planning for Real-World Buildings

From compact residences to multi-zone commercial spaces, the correct system depends on the building layout, usage, load profile and installation conditions.

Residential

Homes & Villas

Multi-room comfort with fewer outdoor units, with zoning planned around bedrooms, living spaces and other occupied areas.

ENQUIRE NOW →
Light Commercial

Offices & Retail

Flexible zoning for cabins, work areas, meeting rooms, shops and showrooms with project-specific indoor-unit selection.

ENQUIRE NOW →
Commercial

Large HVAC Projects

Capacity planning, piping design, installation coordination, commissioning and service support for larger multi-zone projects.

ENQUIRE NOW →

Planning a Daikin VRV Project?

Send us the floor plan, room schedule or project details. We can discuss the right VRV approach from design through execution.

*All model/capacity information is for website reference and preliminary project discussion. Final selection should follow the latest Daikin India technical documentation, project heat-load calculations and site conditions.