Daikin VRV Systems for Homes, Offices & Commercial Projects
Focus Aircon handles VRV projects as a complete HVAC scope — from site assessment and system planning to capacity selection, indoor-unit zoning, refrigerant piping, installation, testing, commissioning and after-sales support.
Daikin model availability and final system selection should be confirmed against the latest project-specific technical documentation before quotation.
Daikin VRV Solutions for Different Project Sizes
For Focus Aircon's project work, it is useful to separate residential VRV, small-office VRV and larger commercial VRV rather than mixing every range into one catalogue.
VRV Home
Compact single-outdoor-unit VRV designed for residences where several indoor units need to be connected while reducing the number of outdoor units.
VRV S
A compact VRV platform aimed at small offices and shops, with a wider capacity range than VRV Home and a choice of indoor and outdoor units.
VRV Alpha
High-capacity Daikin VRV outdoor units for larger offices, showrooms and commercial HVAC applications, with single outdoor modules available across multiple HP classes.
Daikin VRV Home — 4 HP, 5 HP & 6 HP
Designed for homes and residences where multiple rooms can be connected to one outdoor system. Daikin India lists both heat-pump and cooling-only outdoor-unit variants.
Heat Pump Series
| Outdoor model | Capacity | Typical use |
|---|---|---|
| RXYRQ4ARV16 | 4 HP · 11.2 kW | Smaller homes / apartments |
| RXYRQ5ARV16 | 5 HP · 14.0 kW | Medium-size residences |
| RXYRQ6ARV16 | 6 HP · 16.0 kW | Larger homes / villas |
Cooling Only Series
| Outdoor model | Capacity | Variant |
|---|---|---|
| RXRQ4ARV16 | 4 HP · 11.2 kW | Cooling only |
| RXRQ5ARV16 | 5 HP · 14.0 kW | Cooling only |
| RXRQ6ARV16 | 6 HP · 16.0 kW | Cooling only |
Daikin VRV S Outdoor Models by HP Capacity
VRV S is positioned by Daikin India for small offices and shops. The outdoor range listed by Daikin spans 4 HP through 12 HP, giving more capacity steps for light-commercial projects.
| Outdoor model | HP | Cooling capacity | Application context |
|---|---|---|---|
| RX(Y)MQ4BRV16 | 4 HP | 11.2 kW | Small office / shop |
| RX(Y)MQ5BRV16 | 5 HP | 14.0 kW | Small office / shop |
| RX(Y)MQ6ARV16 | 6 HP | 16.0 kW | Office / retail |
| RX(Y)MQ8ARY16 | 8 HP | 22.4 kW | Medium light-commercial space |
| RX(Y)MQ10BRY16 | 10 HP | 28.0 kW | Medium office / retail |
| RX(Y)MQ12BRY16 | 12 HP | 33.5 kW | Larger light-commercial space |
Single-Outdoor Daikin VRV Alpha Models
For larger office and commercial projects, this page focuses on single outdoor-unit models. Combination-unit configurations can be engineered later when a project requires more capacity.
Cooling Only · RXQ Series
| Model | HP | Cooling |
|---|---|---|
| RXQ6BRY16 | 6 HP | 16.0 kW |
| RXQ8BRY16 | 8 HP | 22.4 kW |
| RXQ10BRY16 | 10 HP | 28.0 kW |
| RXQ12BRY16 | 12 HP | 33.5 kW |
| RXQ14BRY16 | 14 HP | 40.0 kW |
| RXQ16BRY16 | 16 HP | 45.0 kW |
| RXQ18BRY16 | 18 HP | 50.0 kW |
| RXQ20BRY16 | 20 HP | 56.0 kW |
| RXQ22BRY16 | 22 HP | 61.5 kW |
| RXQ24BRY16 | 24 HP | 67.0 kW |
| RXQ26BRY16 | 26 HP | 73.0 kW |
Heat Pump · RXYQ Series
| Model | HP | Cooling | Heating |
|---|---|---|---|
| RXYQ6BRY16 | 6 HP | 16.0 kW | 18.0 kW |
| RXYQ8BRY16 | 8 HP | 22.4 kW | 25.0 kW |
| RXYQ10BRY16 | 10 HP | 28.0 kW | 31.5 kW |
| RXYQ12BRY16 | 12 HP | 33.5 kW | 37.5 kW |
| RXYQ14BRY16 | 14 HP | 40.0 kW | 45.0 kW |
| RXYQ16BRY16 | 16 HP | 45.0 kW | 50.0 kW |
| RXYQ18BRY16 | 18 HP | 50.0 kW | 56.0 kW |
| RXYQ20BRY16 | 20 HP | 56.0 kW | 63.0 kW |
| RXYQ22BRY16 | 22 HP | 61.5 kW | 69.0 kW |
| RXYQ24BRY16 | 24 HP | 67.0 kW | 73.0 kW |
| RXYQ26BRY16 | 26 HP | 73.0 kW | 73.0 kW |
Build the VRV Around the Building — Not Just the Outdoor Unit
We can plan the indoor-unit mix around each room, floor and usage pattern. Depending on the project, VRV systems can use wall-mounted, cassette, ducted and other compatible indoor-unit formats.
From First Site Visit to Final Handover
Because VRV is a project-based HVAC system, our role should be presented as complete project execution — not simply supply of an outdoor unit.
Site Survey
Review floor plans, room usage, ceiling conditions, outdoor-unit locations, access and installation constraints.
Load & Capacity Planning
Assess cooling requirements and determine suitable outdoor and indoor-unit capacities for each zone.
HVAC Planning & Layout
Plan indoor-unit locations, outdoor units, piping routes, refnets, drainage, controls and service access.
BOQ & Proposal
Prepare the equipment schedule, piping/material scope and project quotation based on the design.
Installation
Execute outdoor and indoor installation, refrigerant piping, insulation, drainage, wiring and controls.
Testing & Pressure Checks
Carry out the required installation checks, pressure testing, leak checks and evacuation before commissioning.
Commissioning
Start up the system, configure controls and verify operating performance across the connected zones.
Handover & AMC
Complete client handover and continue with preventive maintenance and service support when required.
VRV Planning for Real-World Buildings
From compact residences to multi-zone commercial spaces, the correct system depends on the building layout, usage, load profile and installation conditions.
Homes & Villas
Multi-room comfort with fewer outdoor units, with zoning planned around bedrooms, living spaces and other occupied areas.
ENQUIRE NOW →Offices & Retail
Flexible zoning for cabins, work areas, meeting rooms, shops and showrooms with project-specific indoor-unit selection.
ENQUIRE NOW →Large HVAC Projects
Capacity planning, piping design, installation coordination, commissioning and service support for larger multi-zone projects.
ENQUIRE NOW →Planning a Daikin VRV Project?